Cutback Bitumen SC

The industry is sometimes in need of low viscosity bitumen. There manufacturers came to a solution to deliver cutback bitumen which is a low viscosity liquid dissolved in a solvent. The main advantage of this type of bitumen is that there is no need to heat it before using.

Cutback bitumen is made by the addition of controlled amounts of petroleum extracts such as kerosene, naphtha, diesel oil, and furnace oil to perform as a solvent.

Although these adhesive materials are added to lessen the need for heating before using, they will evaporate as the bitumen is applied. This process is done for a temporary reduction of the bitumen viscosity.

Cutback bitumen is more appropriate for cold regions than the others. Primer sealing and sprayed sealing are some items for which cutback bitumen is suitable.

Specification SC

SC 30

Properties TEST METHOD MAX MIN.
KINEMALIC 1 VISCOSITY AT 60°C, EST ASTM D2170 60 30
FLASH POINT (TAG OPEN-CUP),°C ASTM D1310 65
DUCTILITY 3 AT 25°C, CM ASTM D402 / ASTM D113 100
SOLUBILITY IN TRICHLOROETHYLENE, PERCENT MASS ASTM D402 / ASTM D2024 100
WATER, PERCENT VOLUME ASTM D95 0.2

SC 70

Properties TEST METHOD MAX MIN.
KINEMALIC  VISCOSITY AT  60°C (140°F), mm²/s ASTM D2170 140 70
FLASH POINT (Cleveland open cup),°C ASTM D92 60
Ductility of 100 penetration residue at 25°C (77°F), cm ASTM D113 50
SOLUBILITY % ASTM D2024 95
WATER, PERCENT VOLUME ASTM D95 0.5
Total distillate to 360°C (680°F), volume % ASTM D402 35
Kinematic viscosity on distillation residue at 60°C (140°F), mm²/s ASTM D2170 7000 200

SC 250

Properties TEST METHOD MAX MIN.
KINEMALIC  VISCOSITY AT  60°C (140°F), mm²/s ASTM D2170 500 250
FLASH POINT (Cleveland open cup),°C ASTM D92 60
Ductility of 100 penetration residue at 25°C (77°F), cm ASTM D113 50
SOLUBILITY % ASTM D2024 95
WATER, PERCENT VOLUME ASTM D95 0.5
Total distillate to 360°C (680°F), volume % ASTM D402 25
Kinematic viscosity on distillation residue at 60°C (140°F), mm²/s ASTM D2170 10000 400

SC 800

Properties TEST METHOD MAX MIN.
KINEMALIC  VISCOSITY AT  60°C (140°F), mm²/s ASTM D2170 1600 800
FLASH POINT (Cleveland open cup),°C ASTM D92 70
Ductility of 100 penetration residue at 25°C (77°F), cm ASTM D113 50
SOLUBILITY % ASTM D2024 95
WATER, PERCENT VOLUME ASTM D95 0.5
Total distillate to 360°C (680°F), volume % ASTM D402 15
Kinematic viscosity on distillation residue at 60°C (140°F), mm²/s ASTM D2170 16000 1000

SC 3000

Properties TEST METHOD MAX MIN.
KINEMALIC  VISCOSITY AT  60°C (140°F), mm²/s ASTM D2170 6000 3000
FLASH POINT (Cleveland open cup),°C ASTM D92 70
Ductility of 100 penetration residue at 25°C (77°F), cm ASTM D113 50
SOLUBILITY % ASTM D2024 95
WATER, PERCENT VOLUME ASTM D95 0.5
Total distillate to 360°C (680°F), volume % ASTM D402 8
Kinematic viscosity on distillation residue at 60°C (140°F), mm²/s ASTM D2170 35000 2000
Send Inquiry

FREE QUOTE

Do you need help? Fill out this form to get in touch.